3. Components
3
.1. Base Unit
The Pur•Chek™ Pro base unit (shown in Figure 3-1) houses the graphic display, infrared bench, electrical
connections, and printer module. These components require no maintenance.
IMPORTANT: T
her
e are no serviceable components internal to
the instrument, and
disassembly will void the warranty.
Fi
g
ure 3-1. Base Unit Showing Key Components
3.2. Low Side Vapor Sample Hose
The 8.5 foot (2.5 meter) low side vapor sample hose configuration is constructed of a polyurethane tube.
See Figure 3-2. A brass flow restrictor acts to reduce pressure at the sample connection point and
reduce the introduction of harmful oil into the machine. The maximum inlet pressure is 500 psig. The hose
is provided with an instrument inlet port mating connector on one end and a 1/4” SAE female flare
coupling nut on the service end.
Figure 3-2. Low Side Vapor Sample Hose
3.3. High Side Liquid Sample Hose
The 8.5 foot (2.5 meter) high side sample hose configuration is constructed of a polyurethane tube with
an oil reservoir. A brass flow restrictor acts to transform liquid refrigerant to vapor at the sample
connection point while the oil trap syringe collects oil and provides a means of expulsion after the test is
complete. The maximum pressure is 500 psig. The syringe is provided with a magnet for attaching it to
the tank. It also is provided with an instrument inlet port mating connector on one end and a 1/4 SA
E
f
emale flare coupling nut on the service end. Refer to Figure 3-3.
Analyzer End
Service End
actoolsupply.com